CLASS-A WATER METER IS-2373
CLASS-A (BULK ENCLOSED) WATER METER IS-2373
METROLOGICAL PERFORMANCE
SIZE (mm) | 40 | 50 | 65 | 80 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | 750 | 900 |
Intermediate Flow Liters per Hour | 10000 | 20000 | 40000 | 62000 | 100000 | 250000 | 400000 | 550000 | 750000 | 1000000 | 1500000 | 2000000 | 2500000 | 3500000 | 4000000 | 5000000 |
Nominal Flow Liters Per Hour | 20000 | 50000 | 80000 | 125000 | 200000 | 500000 | 800000 | 1100000 | 1500000 | 2000000 | 3000000 | 4000000 | 5000000 | 7000000 | 8000000 | 10000000 |
Lower Limit of Flow Liters per Hour | 1000 | 1660 | 2667 | 4160 | 6660 | 16660 | 26660 | 36660 | 50000 | 66660 | 100000 | 133300 | 166600 | 233300 | 266666 | 333300 |
Minimum Start-inflow Liters Per Hour | 400 | 500 | 750 | 1000 | 1500 | 3500 | 5500 | 9000 | 14000 | 20000 | 25000 | 30000 | 35000 | 45000 | 55000 | 65000 |
Pressure Testing kg/Cm2 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 |
Minimum Reading in Liters | 10 | 10 | 10 | 10 | 10 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 1000 | 1000 |
Maximum Reading in liters | 100000000 | 1000000000 | 10000000000 | 100000000000 |
STANDARD
Conforms to IS 2373/1981
SALIENT FEATURES
- Dry dial mechanical driven flange ends.
- Ensures wiper to Keep the dial free from frost for clear reading
- Metallic gears for long life and durability
- Size range from 40mm to 1000mm
WORKING CONDITIONS
- water Temperature 45◦C
- water Pressure ≤ 1Mpa
- Maximum Pressure – 16 Bar
Available two types of curve
- HEAD LOSS CURVE
- ACCURACY CURVE
FLANGS DIMENSIONS
SIZE(mm) | 40 | 50 | 65 | 80 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | 750 | 900 |
Outside die Flange (D) | 145 | 165 | 185 | 200 | 220 | 285 | 340 | 395 | 445 | 505 | 565 | 615 | 670 | 780 | 960 | 1115 |
Thickness of Flange (b)mm | 19 | 19 | 20 | 21 | 22 | 23 | 24.5 | 26 | 27.5 | 29 | 30 | 31.5 | 33 | 36 | 40 | 44 |
Dia of Bolt Circle (C) mm | 110 | 125 | 145 | 160 | 180 | 240 | 295 | 350 | 400 | 460 | 515 | 565 | 620 | 725 | 900 | 1050 |
Number of holes (A) | 4 | 4 | 4 | 4 | 8 | 8 | 8 | 12 | 12 | 16 | 16 | 20 | 20 | 20 | 24 | 28 |
Dia of BoltHoles (d)mm | 19 | 19 | 19 | 19 | 19 | 23 | 23 | 23 | 23 | 23 | 28 | 28 | 28 | 31 | 31 | 34 |
Total Length (L) mm | 170 | 170 | 198 | 198 | 240 | 295 | 343 | 443 | 365 | 530 | 535 | 580 | 610 | 645 | 655 | …….. |
NOTES
- Above particular relate of cold water meters for temperature upto 45◦C.
- As constant efforts are made to improve the design, details given in the leaflet , are subject to change or modify without any prior notice.
- Flanges drilled as per IS: 1538 Part IV&VI
Class-B Water Meter ISO-4064
Class-B (WOLTMAN TYPE) WATER METER ISO-4064
METROLOGICAL PERFORMANCE
Size of meter | Acc(%) | 40mm | 50mm | 65mm | 80mm | 100mm | 150mm | 200mm | 250mm | 300mm | 350 mm | 400mm | 450mm | 500 mm | 600mm | |
Minimum Flow Q min | m3/h | ±5 | 0.3 | 0.45 | 0.75 | 1.20 | 1.80 | 4.50 | 7.50 | 12.00 | 18.00 | 24 | 30.00 | 37.5 | 45.00 | 75.00 |
Transitional flow Qt | m3/h | ±2 | 2 | 3 | 5 | 8 | 12 | 30 | 50 | 80 | 120 | 160 | 200 | 250 | 300 | 500 |
Nominal flow Qn | m3/h | ±2 | 10 | 15 | 25 | 40 | 60 | 150 | 250 | 400 | 600 | 800 | 1000 | 1250 | 1500 | 2500 |
Maximum flow Q max | m3/h | ±2 | 20 | 30 | 50 | 80 | 120 | 300 | 500 | 800 | 1200 | 1600 | 2000 | 2500 | 3000 | 5000 |
Minimum Reading | m3 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | |
Maximum Reading | m3 | 9999999m3 | 9999999m3 x10 | 9999999m3 x100 | ||||||||||||
Temperature Suitability | °c | 45°C | ||||||||||||||
Pressure Test | Kg/cm2 | 20Kg/cm2 |
STANDARD
Conforms to ISO 4064/1 Class-B
APPLICATIONS
Water Distribution Network Industrial commercial Water Supply
SALIENT FEATURES
- Dry dial mechanical driven flange ends.
- Interchangeable spare without interrupting water supply
- Provide resistance against condensation hermetically sealed;IP68
- Offer high measurement sensitivity and accuracy
- Offer Size range from 40mm to 600mm
WORKING CONDITIONS
- Water Temperature 45◦C
- Water Pressure ≤ 1MPa
- Pressure Loss <0.1 MPa
- Maximum Pressure – 16 Bar
OPTIONS
Hot Water Meters (<90°C)
METER DIMENSIONS
Size of meter | 40 mm | 50 mm | 65 mm | 80 mm | 100 mm | 150 mm | 200 mm | 250 mm | 300 mm | 350 mm | 400 mm | 450 mm | 500 mm | 600 mm |
Length (L) mm | 245 | 200 | 200 | 225 | 250 | 300 | 350 | 450 | 500 | 500 | 600 | 600 | 600 | 800 |
Height (H1) mm | 68.5 | 78 | 87 | 95 | 102 | 135 | 162 | 196 | 223 | 254 | 282 | 307 | 334 | 390 |
Height (H2) mm | 185 | 188 | 183 | 182 | 183 | 185 | 213 | 286 | 287 | 321 | 323 | 382 | 396 | 450 |
FLANGES DIMENSIONS
Size of meter | 40 mm | 50 mm | 65 mm | 80 mm | 100 mm | 150 mm | 200 mm | 250 mm | 300 mm | 350 mm | 400 mm | 450 mm | 500 mm | 600 mm |
Dia Bolt Circle (c) | 110 | 125 | 145 | 160 | 180 | 240 | 295 | 350 | 400 | 460 | 515 | 565 | 620 | 725 |
Dia Bolt Holes (d) | 19 | 19 | 19 | 19 | 19 | 23 | 23 | 23 | 23 | 23 | 28 | 28 | 28 | 31 |
Number of Holes (A) | 4 | 4 | 4 | 4 | 8 | 8 | 8 | 12 | 12 | 16 | 16 | 20 | 20 | 20 |
Outside Dia of Flanges (D) | 150 | 165 | 185 | 200 | 220 | 285 | 340 | 395 | 445 | 505 | 565 | 615 | 670 | 780 |
Thickness of Flanges (b) | 19 | 19 | 20 | 21 | 22 | 23 | 24.5 | 26 | 27.5 | 29 | 30 | 31.5 | 33 | 36 |
Class-B Pulse Output/AMR Water Meter
Class-B Pulse Output Water Meter
TECHNICAL DATA:
NORMAL SIZE DN (mm) | Class of measurement | Overload flow-rate qs (m 3 h) | Permanent flow-rate qp (m 3 h) | Transitional flow-rate qt (m 3 h) | Minimum flow-rate qm | Minimum Reading min (m 3) | Minimum Reading min (m 3) |
40 | B | 20 | 10 | 2.0 | 0.30 | 0.01 | 999999 |
50 | B | 30 | 15 | 3.0 | 0.45 | 0.01 | 999999 |
65 | B | 50 | 25 | 5 | 0.75 | 0.01 | 999999 |
80 | B | 80 | 40 | 8 | 1.2 | 0.01 | 999999 |
100 | B | 120 | 60 | 12 | 1.8 | 0.01 | 999999 |
125 | B | 200 | 100 | 20 | 3 | 0.1 | 999999 |
150 | B | 300 | 150 | 30 | 4.5 | 0.1 | 999999×10 |
200 | B | 500 | 250 | 50 | 7.5 | 0.1 | 999999 x10 |
OVERALL DIMENSIONS AND WEIGHT
Size(mm) | Length(mm) L | Width (mm) H | Height (mm) H | Output diameter of flange D (mm) | The center diameter of connecting bolt D1 (mm) | Connecting bolt (Pcs.) | Weight (kg |
40 | 245 | 165 | 253.5 | 165 | 125 | 4 x 6 | 12 |
50 | 200 | 165 | 266 | 165 | 125 | 4 x M16 | 12 |
65 | 200 | 185 | 270 | 185 | 145 | 8 x M16 | 13 |
80 | 225 | 200 | 277 | 200 | 160 | 8 x M16 | 15 |
100 | 250 | 220 | 285 | 220 | 180 | 8 x M20 | 19 |
125 | 250 | 250 | 320 | 250 | 210 | 8 x M20 | 23 |
150 | 300 | 285 | 320 | 285 | 240 | 8 x M20 | 30 |
200 | 350 | 340 | 375 | 340 | 295 | 12 x M20 | 42 |
ACCURACY:
- From minimum flow-rate (qmin) inclusive, to transitional flow-rate (qt), exclusive:±5%
- From transitional flow-rate (qt) inclusive, to overload flow-rate (qs), exclusive:±2% (Hot water meter:±3%)
FEATURES:
- Dry-dial, magnetic drive
- Vacuum sealed register, frost resistant, keeps clear reading for long time
- Removable measuring unit, easy installation and maintenance
- Measuring high flow rate with low head loss
- Remote transmission device can be added upon request many kinds of sensors, such as reed Switch, hall and Wigand can be supplied upon request.
- Pulse output may be, 100L/Pulse, 1000L/Pulse
- The meters conform to ISO4064 Standard Class B
WORKING CONDITION:
- Water temperature<45°C (Hot water meter <90°C)
- Water pressure<1MPa (PN: 1.6 Mpa/16bar)
- P<0.03 Mpa
CHARACTERISTICS:
- All the materials in contact with water, consciously selected by the known resistance to corrosion; cold water meter under current standard for lower than 30 C (T30), but Belanto MULTI G can be used safely in water temperature up to 50 C (T50);
- The ROTARY indicator registers for the most comfortable reading position of 7 Rollers and 2 Pointers;
- The ROTARY plastic cap and lid for the most comfortable installation;
- The Impeller is the only moving parts in contact with water permitting the most reliable;
- The inlet filter at the inlet of the meter body permits cleaning it without breaking the metrological seal; Internal filter as option;
- The conception of the Magnetic Protection to against the external influences; non return valve to avoid the reserve flow rate AS OPTION;
Available two types of curve
- HEAD LOSS CURVE
- ERROR CURVE
SINGLE JET CLASS-B WATER METER IS: 779: 1994 ISO 4064
SINGLE JET CLASS-B WATER METER
SALIENT FEATURE
- Single jet, super dry, straight reading type, hermetically sealed water with magnetic driven totaliser.
- Standard: it complies with IS: 779/94 and class B of ISO:4064
- Brass body and coupling Nut Nipple
- Plastic cap and ring
- Sealed against tampering
- Leakproof, totally dry
- Measuring unit is kiloliters
- Maximum Reading 99999.9999
METER DIMENSIONS
TYPE | Size (mm) | Length mm L | Width (mm) W | Length Including Nipple± 5% | Height (mm) H | Connecting Thead D |
Single Jet | 15 MM | 110 | 77 | 250 | 82 | 3/4 |
Single Jet | 20 MM | 130 | 78 | 290 | 85 | 1” |
WORKING CONDITIONS
- Water Temperature ≤ 45°C
- Water Pressure ≤ 1 MPa (PN: 1.6 MPa/16bar)
ACCURACY:
- From minimum flow-rate (Qmin) inclusive to
- transitional flow-rate (Qt), exclusive:+-5%
- From transitional flow-rate (Qt) inclusive to
- Maximum flow-rate (Qmax), Exclusive:+-2%
PERFORMANCE DATA
Nominal Size DN (mm) | Minimum Reading Quantity In Litres | Hydro Static Test | Maximum Flow Rate in Qmax-Lts/hr | Nominal Flow rate Qn.lts/hr | Transitional flow rate Qn.lts/hr | Minimum Starting Flow Qmin-Its/hr |
15 | 0.2 | 2.0 MPa | 3000 | 1500 | 120 | 30 |
20 | 0.2 | 2.0 MPa | 5000 | 2500 | 200 | 50 |
Available two types of curve
- HEAD LOSS CURVE
- ERROR CURVE
CLASS-B WATER METER IS:779 :1994 ISO 4064
CLASS-B WATER METER (PRIME)
SALIENT FEATURE
- Super dry, straight reading type, hermetically sealed water with magnetic driven totalizer
- Standard: it complies with IS: 779/94 and class B of ISO:4064/1
- Brass body and coupling Nut Nipple
- Plastic cap and ring
- Sealed against tampering
- Leakproof, totally dry
- Measuring unit is kiloliters
- Maximum Reading 99999.9999
WORKING CONDITIONS
- Water Temperature ≤ 45°C
- Water Pressure ≤ 1 MPa
- Maximum Pressure – 16 Bar
ACCURACY:
- From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt), exclusive:±5%
- From transitional flow-rate (Qt) inclusive, to Maximum flow-rate (Qmax), Exclusive:±2%
PERFORMANCE DATA
Nominal Size DN (mm) | Minimum Reading Quantity In Litres | Hydro Static Test | Maximum Flow Rate in Qmax-Lts/hr | Nominal Flow rate Qn.lts/hr | Transitional flow rate Qn.lts/hr | Minimum Starting Flow Qmin-Its/hr |
15 | 0.1 | 2.0MPa | 3000 | 1500 | 120 | 30 |
METER DIMENSIONS
Type | Size (mm) | Length mm L | Width (mm) w | Length Including Nipple ± 5% | Height (mm) H | Connecting Thread D |
Multi Jet | 15 mm | 165 | 81 | 250 | 100 | ¾” |
FEATURE:
- Dry dial, vacuum sealed to keep clean reading for long time available for cold water 0-45°C and hot water 0-45°C-90°C
- Magnetic transmission
- Ant magnetic type
UPON REQUEST:
- Remote Transmission device can be added upon request
- Pulse output 10L/Pulse
Available two types of curve
- HEAD LOSS CURVE
- ERROR CURVE
CLASS-B WATER METER AMR COMPATIBLE
CLASS-B WATER METER AMR COMPATIBLE
Type | Size (mm) | Length (mm) L | Length including nut nipple (mm) | Width (mm) W | Height (mm) W | Connecting Thread D |
15 | 165 | 250 | 97 | 109 | G ¾ B | |
20 | 190 | 290 | 98 | 110 | G 1 B | |
25 | 260 | 380 | 104 | 117 | G ¼ B | |
40 | 300 | 430 | 125 | 148 | G 2 B | |
50 | 330 | 470 | 125 | 148 | G2 ½ B |
- Dry-dial, magnetic drive, protected against external magnetic tampering;
- Vacuum sealed register, frost resistant, keeps clear reading for long time
- Brass body, cast body or plastic body, optional;
- Internal or external adjusting device, optional;
- The meters conform to IS:779:1994 / ISO-4064/1 Standard Class B;
WORKING CONDITIONS
- Water Temperature ≤ 45°C
- Water Pressure ≤ 1 MPa
- Maximum Pressure – 16 Bar
ACCURACY:
- From minimum flow rate (Qmin) inclusive, to transitional flow-rate (Qt), Exclusive:±5%
- From transitional flow rate (Qt) inclusive, to Maximum flow-rate (Qmax), Exclusive:±2%
PERFORMANCE DATA
Nominal Size DN (mm) | Minimum Reading Quantity In Liters | Hydro Static Test | Maximum Flow Rate in Qmax-Lts/hr | Torminal Flow rate Qn.lts/hr | Transitional flow rate Qn.lts/hr | Minimum Starting Flow Qmin-Its/hr |
15 | 0.1 | 2.0MPa | 3000 | 1500 | 120 | 30 |
20 | 0.1 | 2.0MPa | 5000 | 2500 | 200 | 50 |
25 | 0.1 | 2.0MPa | 7000 | 3500 | 280 | 70 |
40 | 0.1 | 2.0MPa | 20000 | 10000 | 800 | 200 |
50 | 0.1 | 2.0MPa | 30000 | 15000 | 1200 | 300 |
MECHAICAL OIL METER DM-01
MECHAICAL OIL METER DM-01
PETROLEUM METERING EQUIPMENT & ACCESSORIES
Mechanical volumetric flow-meter for private use, with Nutating-disc type chamber for delivers to 120 LPM. It can be installed for gravitational feeding, as well as for hand operated or electric transfer pumps with by-pass arrangement.
TECHNICAL DATA | DM-01 |
Meter mechanism | Nutating disk |
Flow-rate (range) | 20-120 I/mm (5.28-31.7 Gal/min) |
Operating pressure (max) | 3.5 bar 49(psi) |
Brust pressure (max) | 30 bar (420psi) |
Storage time (range) | -20-+80 o |
Storage humidity (max) | 95% |
Oprating temperature (range | -10-+60 o |
Accuracy after calibration | +/-1% |
Repeatability (typical) | +/-0.3% |
Readout solution | 0.1 L/Gal |
Connection (inlet/outlet) | 1 inch BSP/NPT |
Weight (approximate) Package dimension | 1.8KG 18 X 16 X 14 cm |
Technical Performance:
- Connecting Style: NPT/BSPP thread
- Material: Aluminium weight: about 0.8 kgs.
- Flow range: 25 MM (1”) 18.9-190 LPM 40 MM(1-1/2”) 38.0 – 380 LPM
- Accuracy: 25 mm ± 1.0%, 40mm ± 0.5%
- Repetition: ± 0.1%
Fluid Compatibility:
The DM-01 series meter are compatible with the following fluids: Diesel, Gasoline, Kerosene, Methanol
Installation:
- The oil meter could be install in any position, for non horizontal positions the flow shall upwards.
- The meter shall be full of oil while operation
- Prior to installation of a meter, the pipeline shall be thoroughly flushed.
- Straight pipe section of the same diameter S as the meter, having length of 10D and 5D shall be installed upstream and downstream of the meter respectively.
Pressure Class:
- Pressure: 300 psi
- Working pressure: 2-10 bar
- Supposed fitter dimension: 55 mesh
ULTRASONIC FLOW METER
ULTRASONIC FLOW METER
SALIENT FEATURE
- Long-term stability and accuracy over a wide range of conditions
- High reliability and minimum maintenance requirement
- No need for external power
- Communication port permits transfer of data from remote stations to central system via GSM-GPRM modem
- Self-adjusting transducer receiving circuit continually adapts to changing pipe diameters due to scaling or corrosion
- Available with AMR function
- Battery life-5 years (10 years optional)
DESCRIPTION
This is Battery Powered, Transit Time Flow Meter Utilizing Advanced Digital processing Technology. The meter contains no Moving parts and does not Require External Power. It also has Advantages such as ultra Low Power Consumption, High Accuracy and Reliability. The meter is Designed for Easy Installation. It has the same conduit length as industrial Mechanical Water Meter, But can be used just as conveniently as a mechanical water.
Technical Specification
Technical Characteristics | Low power consumption, digital pricess technology with stable and permanent Piezo Seal sensor |
Accurace | ±1% of reading (optional ±0.5%) |
Repeatabity | 0.2% of span |
Display | Total flow, flow rate, velocity, working time & date, signal intensity, quality and Battery status |
Output | 4-20mA, Pulse for total flow (all outpurs need external power supply 24 V DC) |
Communication interface | GSM, GPRS |
Operation | Inside keypad available |
Sampling period | 0.5 sec. |
Environment Temp. | Up to 70°C |
Water Temp. | 5 to 70° C |
Power Supply | 3.6 V Lithium battery |
Eclosure Class | IP 68 |
Pipe Size | DIN 16-600 |
Flange standard | DIN, ANSI 150, BS |
ULTRASONIC CLAMP FLOW METER
ULTRASONIC FLOW METER CLAMP TYPE
The Transit Time Flowmeter utilizes two transducers that function as both, ultrasonic transmitters and Receivers. The transducers are clamped on the outside of a closed pipe or inserted in the pipeline by using an isolating ball valve assembly at a specific distance from each other. Transit Time Flow meters measure the time it takes for an ultrasonic signal transmitted from one sensor to cross a pipe and be received by a second sensor. Upstream and with flow, sound will travel faster in the direction of the flow and slower against the flow. The liquid velocity (V) inside the pipe can be related to the difference in time of flight
( t) through the following equation:
V = KxDx t where
V : Liquid velocity
K : Constant
D : Distance between the two trasducers
t : Difference in time of fligh
Power Supply | 24 V DC± 20 110 V AC± 15% 240 V AC ± 15% |
Velocity | ±12 m/sec ,Bidirectional |
Display | 2 lines,16 characters, LCD with backlight, flow rate velocity, totaliser |
Units | User configurable English/Metric |
Totaliser | FWD, NET, REV, BATCH (Gallons, ft3,Barrels,Ibs,m3) |
Output | 4-20 m A DC Std.* |
Accuracy | ±1% of reading @ ate > 0.5 m/sec. (Optional ± 0.5% of reading) |
Repeatability | 0.2% of Span |
Dimensions | 251×190×96 mm |
Weight | ˂2.5 kg |
Security | Keypad lockout, access code enabled |
Suited temp. – Std. | -40◦C to 120◦C |
Suited temp. – High | -40◦C to 250◦C |
Pipe Size | S Transducer 15-80 mm M Transducer 50-700mm L Transducer 400-4570 mm |
Dimensions | S Transducer 45×30×30 mm M Transducer 60×45×45 mm L Transducer 80×70×55 mm |
Weight | S Transducer ˂0.3 kg M Transducer ˂ 0.5 kg L Transducer ˂ 1.0 kg |
Cable length | 6 m Std. can be extended up to 300 m |
Flexible belts | SS belt according to pipe size |
Portable case | NA |
INSERTION FLOW METER
K-04 are Insertion type electromagnetic flow transmitter specially used for various industrial application. These flow transmitters accurately measures to flow ratye of conductive liquids & slurries in closed pipes. Due to simple & rigid design the flow transmitter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device. The use of ‘Pulsed DC’ technology offer highest ability & better measuring accuracy in the form of electrical signal 4-20 mA DC linearly proportional to volumetric flow. The instrument is based on Faraday’s law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a coltage that is proportional to the velocity. Corresponding electrical output is provided with respect to measuring voltage.
Media | Liquid(Clear) |
Viscosity | 200 cp max |
Line size | 100 NB to 2000 NB |
Excitation | Pulsed DC coll |
Type of outputs | 4 to 20 m A DC |
Calibration Range | As per requirement (Factory Calibrated) |
Accuracy | +/ – 0.5% F.S. |
Linearity | + / -0.5 % |
Repeatability | +/-1% |
Process Temperature | 120 kg/cm2 max |
Material of construction | Electrode SS316 , Retractable Assembly MS/SS, wetted Parts – SS316 |
Power supply | 1)230 V AC, 50Hz +/- 10% 2)24 V DC, External |
Power Consumption | ˂ 10 VA |
Response Time | ˂ 100m Sec |
Temperature Coefficient | Flame-proof, IP-65, IIA,IIB CMRI certified |
Mounting | Insertion Type |
Operating Conditions | Temperature 0 to 55◦C Humidity 5 to 55% non Condensing |
Installation | Insertion type with use of isolating ball valve assembly on pipe line |
Line Size (mm) | Flow (m3/hr) | Flow (MLD) | Flow (ft3/sec) |
200 | 113.10 | 2.714 | 1.109 |
250 | 176.71 | 4.241 | 1.734 |
300 | 254.47 | 6.107 | 2.496 |
350 | 346.36 | 8.313 | 3.398 |
400 | 452.39 | 10.857 | 4.438 |
500 | 706.86 | 16.965 | 6.934 |
600 | 1017.88 | 14.429 | 9.985 |
700 | 1385.44 | 33.250 | 13.251 |
800 | 1809.56 | 43.429 | 17.751 |
900 | 2290.22 | 54.965 | 22.466 |
1000 | 2827.43 | 67.858 | 27.736 |
1200 | 4071.50 | 97.716 | 39.940 |
1400 | 5541.76 | 133.002 | 54.363 |
1600 | 7238.22 | 173.717 | 71.004 |
1800 | 9160.88 | 219.861 | 89.865 |
2000 | 11309.72 | 271.433 | 110.944 |
Electromagnetic Flow meters
FM-12
(for conductive liquid) German technolog HART,4-20Ma 0.5% accuracy ± 1% accuracy.
For harsh operating condition, it may realize high standard stable measurement accuracy is not affected by the changes of fluid density, viscosity, temperature and pressure.
- No components stopping flowing in the pipe
- Low pressure loss
- Maintenance-free
- Low requirement of the straight pipe section.
The sensor may have grounded electrode to realize sound grounding of meter. All-digital processing, strong anti-interference ability, reliable measuring, high accuracy.
Bi-direction flow measurement; bi-direction flow total cumulative function.
Application:
Refineries, waste oil, petrochemical , Segar with textile mills ,ETP
Size:
15mm-300mm
Mechanical Meter
FM-01
Petroleum Matering Equipment $ Accessories
Mechanical volumetric flow- meter for private use, with mutating –disc type chamber for deliveries to 120 1/min. It can be installed for gravitational feeding, as well as for hand operated or electric transfer pumps with by-pass arrangement.
Performance
- Recommended flow range : 20 to 120 LMP
- Rated accuracy : ±2%
- Maximum pressure : 50PSIG
- Meter digit indication :9999 literes(resettable)
- Totalizer digit indication: 99999999 literes (non resettable)
- Temperature range : 10°c to 50°c
Fluid compatibility
The FM-01 series meter are compatible with the following fluids:
Diesel fuel, gasoline ,kerosene, methanol
Electronic Digital Turbine Flow-meter
High accuracy,everlasting small volume turbine flowmeter module design can be used with output module, sensor and long –distance transfer. Has the same function it is easy to change the spare parts inside,and easy to maintain it is easy to assembling as its cabinet and compact design lithium battery, can supply 9000 hr power technical performance.
Technical Performance:
Connecting style: NPT/BSPP thread
Material: Aluminium
weight: about 0.8kgs.
Flow range:
- ¾- 2.206GPM(75.7LPM)
- 1”5-50GPM(18.9-190LPM)
- 1-1/2”10-100GPM(38.0-380LPM)
Accuracy: 3/4”±1.0%, 1”±1.0%, 1-1/2” ±0.5%
Repetition: ±0.1%
Pressure class:
Max .pressure : 300psi
Working pressure : 2-1bar
Supposed filter dimension: 55mesh
Vortex steam Flow Meter
The FM-14 as a compact flow meter in a in a flange/sandwhich vesion is suitable for universal use in measuring liquids, gases and vapours.
The temperature compensation for saturated steam is integrated as standard, thus enabling direct compensation of the density the mass and energy can also be measured.
Size: 15mm-300mm
- 2-wire device with integrated pressure and temperature compensation
- Non-wearing ,fully welded stainless steel construction with high corrosion, pressure and temperature resistance.
- Ready to use immediately thanks to plug $ play.
- Maintenance – free sensor design
Use for- chemical, oil $ gas, power plants, iron, steel and metal, papper and pulp, water $ automation.
Application:
- Vapour and saturated steam measurement.
- Steam boiler monitoring
- Monitoring of compressor output
- Measurement of consumption of industrial gases
- SIP and CIP processes in the food ,beverage and pharmaceutical industries
- Measurement of consumption and non- conductive liquids.